Fanuc ALPHA E series alarms

Fanuc ALPHA E series servo alarms. These alarm and error codes cover the A06B-6070 and the drive section of the Power Mate-Model E which is a PM and single axis servo drive. Please contact us if you need testing, a repair or an exchange part. For further information please visit our dedicated E series product pages A06B-6070-H005, A06B-6070-H004 and PM model E A02B-0168-B012 and A02B-0168-B053 and variations.

This page addresses only the drive alarms of the E series servo drive. Please click too visit PM model E alarms.

Alarm CodeTypeDescription of Alarm/Error
HCHigh CurrentFault caused within the servo amplifier, E series servo motor or issues with the command signal from control. Alternatively power cable and signal cable can cause the HV alarm.
HVHigh VoltageServo unit is detecting high voltage in the input voltage.
OHEOverheat ExternalThis alarm occurs if the temperature of the motor is abnormally high
OHIOverheat InternalThis alarm occurs if the temperature of the amplifier is abnormally high

These drives have the following Fanuc battery fitted A02B-0168-K111. Further we have testing and repair facilities for these E series servo units. Some were fitted with controls such as the Fanuc 20-TA with no display reliant on a mobile HMI operating between many machines.