Alarm Code
|
Description of Alarm/Error
|
1
|
Inverter: Internal cooling fan stopped |
2
|
Inverter: Control power supply under voltage |
5
|
Inverter: DC link under voltage |
6
|
Inverter: Overheat |
8
|
Inverter: DC link current alarm (L axis) |
8.
|
Inverter: IPM alarm (L axis) |
9
|
Inverter: DC link current alarm (M axis) |
9.
|
Inverter: IPM alarm (M axis) |
Blinking
|
Inverter: abnormal control power supply |
A
|
Inverter: DC Link Current alarm (N axis) |
A.
|
Inverter: IPM alarm (N axis) |
b
|
Inverter: DC Inverter: Control Command Failure |
c
|
Inverter: DC Inverter: Control Command Failure |
d
|
Inverter: DC Inverter: Control Command Failure |
F
|
Inverter: cooling fan stopped of the radiator |
P
|
Inverter: Communication error between amplifier and module |
U
|
Inverter: FSSB communication error (COP10B) |
L
|
Inverter: FSSB communication error (COP10A) |